HANWEST C/PAD TO SUIT PCB-079HPS-1010 2Z

Stock Code:
RE705-1
Regular Price: $212.47 (inc GST)
Regular Price:
$212.47 (inc GST)
Price:
$136.13 (inc GST)
Quantity Breaks
1+
$136.13 (inc GST)

Details

  • In Stock Unit:
    Each

Description

“WCS” SERIES AIR CONDITIONING CONTROL FOR APARTMENTS – HOTELS - OFFICES

Features:

  • Easy to read backlight LCD display.
  • Select temperature in 0.5°C increments.
  • Single or dual sensors averaging.
  • Check temperature of each zone.
  • Slim profile only 12mm.
  • Mounting fits standard wall bracket control.
  • 12 hour on delay/off delay
  • 3 speed indoor fan control

The WCS-201HZ controller provides you with the following choice of operating modes.

FAN - The fan mode turns on the indoor fan to provide air circulation to the areas served by the air conditioner. In this mode no heating or cooling operation takes place. 

COOL - When cool is selected the air conditioner will operate to provide cooling until the set point temperature is reached.

HEAT - In heat mode the air conditioner will switch on the heating function  until the set point temperature is achieved.

AUTO - With the selection of auto mode the air conditioner will automatically start the heating or cooling function of the air conditioner to raise or lower the temperature of the air conditioned area to the set point temperature. 

Temperature Adjustment.
To adjust the set point temperature, press the set temp. "UP" or "DOWN" tab until the required temperature is selected. Each press of the "UP" or "DOWN" tab will change the set point temperature 0.5°C. The set point temperature is displayed in large characters in the centre of the display window.

Fan Speed Setting.
The WCS-201HZ controller allows you the choice of 3 fan speed selections. HIGH - MEDIUM - LOW. To select the required fan speed press the "FAN SPEED" tab. Repeated pressing of the fan speed tab will change the selection and the selected speed will be displayed in the left hand side of the display window. High ⇒ Med. ⇒ Low ⇒ High.

In heat mode an additional feature allows you to select continuous fan operation or auto fan operation. High ⇒ Med. ⇒ Low ⇒ Cont. + High ⇒ Cont+ Med⇒ Cont+ Low. When Cont. is selected the indoor fan will run continuously when the air conditioner is turned on in the Heat mode. When HEAT mode is selected and the Cont. is off the fan will stop when the set point temperature is reached and the heat operation is turned off. The fan will run on for 3 minutes after the air conditioner heater turns off to dissipate any residual heat in the heating device. If the air conditioner is turned off during the heating operation the indoor fan will continue to run for 3 minutes to dissipate any residual heat in the heating device.


Count Down Timer-On Setting.
With control off in standby mode, depress timer button. The digital display will change to timer display while adjustment is being carried out. Using timer button select number of hours until unit is to switch on. The display will .remain on and will countdown the number of hours until the control switches on. The air conditioner will start automatically after the set number of hours.

Count Down Timer-Off Setting.
With unit operating depress timer button. The digital display will change to timer display whilst adjustment is being carried out. Using timer key select number of hours until the control is to switch off. Display will revert back to room temperature 20 seconds after the last button depression. Unit will be placed into Standby mode after the set number of hours.

Zone Control Models.
For WCS-201HZ models that have control tabs to switch 2 zones on or off, the operation is as follows.
To prevent problems with the air conditioner, the control will not allow both zones to be turned off. "Zone 1" is generally the main zone and if "Zone l" is off and "Zone 2" on, if "Zone 2" is turned off "Zone l" will automatically turn on.
To turn a zone on or off simply press the zone tab. The wording "Zone 1" and/or "Zone 2" will be displayed in the bottom of the display window when the zone is turned on.

 

Please log in for more technical information.