SCHNEIDER TIME DELAY RELAY 0.05s 300h

Stock Code:
SE-TDR005
Regular Price: $130.74 (inc GST)
Regular Price:
$130.74 (inc GST)
Price:
$81.65 (inc GST)
Quantity Breaks
1+
$81.65 (inc GST)

Details

  • In Stock Unit:
    EACH

Description

Main 

range of productHarmony Timer Relays
product or component typeDual function relay
discrete output typeRelay
device short nameRE22
nominal output current8 A

 

COMPLEMENTARY

contacts type and composition1 C/O timed contact, cadmium free
time delay typePower on-delay
time delay range3...30 s
30...300 s
10...100 s
0.05...1 s
1...10 s
30...300 h
30...300 min
0.3...3 s
3...30 h
3...30 min
control typeRotary knob
Diagnostic button
[Us] rated supply voltage24...240 V AC/DC 50/60 Hz
Release input voltage<= 2.4 V
voltage range0.85...1.1 Us
supply frequency50...60 Hz +/- 5 %
connections - terminalsScrew terminals, 1 x 0.5...1 x 3.3 mm² (AWG 20...AWG 12) solid without cable end
Screw terminals, 2 x 0.5...2 x 2.5 mm² (AWG 20...AWG 14) solid without cable end
Screw terminals, 1 x 0.2...1 x 2.5 mm² (AWG 24...AWG 14) flexible with cable end
Screw terminals, 2 x 0.2...2 x 1.5 mm² (AWG 24...AWG 16) flexible with cable end
tightening torque0.6…1 N.m conforming to IEC 60947-1
housing materialSelf-extinguishing
repeat accuracy+/- 0.5 % conforming to IEC 61812-1
temperature drift+/- 0.05 %/°C
voltage drift+/- 0.2 %/V
setting accuracy of time delay+/- 10 % of full scale at 25 °C conforming to IEC 61812-1
Control signal pulse width100 ms with load in parallel
30 ms
insulation resistance100 MOhm at 500 V DC conforming to IEC 60664-1
Recovery time120 ms on de-energisation
immunity to microbreaks10 ms
power consumption in VA3 VA at 240 V AC
power consumption in W1.5 W at 240 V DC
switching capacity in VA2000 VA
minimum switching current10 mA at 5 V DC
maximum switching current8 A
maximum switching voltage250 V AC
electrical durability100000 cycles, 8 A at 250 V, AC-1
100000 cycles, 2 A at 24 V, DC-1
mechanical durability10000000 cycles
Rated impulse withstand voltage5 kV for 1.2…50 µs conforming to IEC 60664-1
Power on delay100 ms
creepage distance4 kV/3 conforming to IEC 60664-1
overvoltage categoryIII conforming to IEC 60664-1
safety reliability dataMTTFd = 308.2 years
B10d = 280000
mounting positionAny position
mounting support35 mm DIN rail conforming to EN/IEC 60715
status LEDLED backlight green (steady) for dial pointer indication
LED yellow (steady) for output relay energised
LED yellow (fast flashing) for timing in progress and output relay de-energised
LED yellow (slow flashing) for timing in progress and output relay energised
width22.5 mm
net weight0.1 kg

 

ENVIRONMENT

dielectric strength2.5 kV for 1 mA/1 minute at 50 Hz between relay output and power supply with basic insulation conforming to IEC 61812-1
standardsUL 508
IEC 61812-1
directives2006/95/EC - low voltage directive
2004/108/EC - electromagnetic compatibility
product certificationsCE
UL
GL
CCC
EAC
RCM
CSA
ambient air temperature for operation-20…60 °C
ambient air temperature for storage-40…70 °C
IP degree of protectionIP40 housing: conforming to IEC 60529
IP50 front face: conforming to IEC 60529
IP20 terminals: conforming to IEC 60529
pollution degree3 conforming to IEC 60664-1
vibration resistance20 m/s² (f= 10…150 Hz) conforming to IEC 60068-2-6
shock resistance15 gn not operating for 11 ms conforming to IEC 60068-2-27
5 gn in operation for 11 ms conforming to IEC 60068-2-27
relative humidity95 % at 25…55 °C
electromagnetic compatibilityFast transients immunity test - test level: 1 kV level 3 (capacitive connecting clip) conforming to IEC 61000-4-4
Surge immunity test - test level: 1 kV level 3 (differential mode) conforming to IEC 61000-4-5
Surge immunity test - test level: 2 kV level 3 (common mode) conforming to IEC 61000-4-5
Electrostatic discharge - test level: 6 kV level 3 (contact discharge) conforming to IEC 61000-4-2
Electrostatic discharge - test level: 8 kV level 3 (air discharge) conforming to IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test - test level: 10 V/m level 3 (80 MHz...1 GHz) conforming to IEC 61000-4-3
Conducted RF disturbances - test level: 10 V level 3 (0.15...80 MHz) conforming to IEC 61000-4-6
Fast transient bursts - test level: 2 kV level 3 (direct contact) conforming to IEC 61000-4-4
Immunity to microbreaks and voltage drops - test level: 30 % (500 ms) conforming to IEC 61000-4-11
Immunity to microbreaks and voltage drops - test level: 100 % (20 ms) conforming to IEC 61000-4-11

 

PACKING UNITS 

Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Weight92.0 g
Package 1 Height2.6 cm
Package 1 width8.2 cm
Package 1 Length9.5 cm
Unit Type of Package 2S02
Number of Units in Package 240
Package 2 Weight4.261 kg
Package 2 Height15 cm
Package 2 width30 cm
Package 2 Length40 cm
Unit Type of Package 3P06
Number of Units in Package 3640
Package 3 Weight76.676 kg
Package 3 Height75 cm
Package 3 width60 cm
Package 3 Length80 cm